CSCsl34922
Symptom: Dual-fabric DMM migration jobs can not have one fabric running Release 3.2(1a) and a peer
fabric running Release 3.2(2c) due to a signal message change. This may cause unexpected results during
a DMM migration job validation, creation, start, and so on.
Workaround: Run both fabrics with the same software image.
CSCsi56167
Symptom: The response time shown in the output of a ping ip-address command may not be accurate if
there is an MDS MSM-8/4 in the path.
Workaround: Use the ips measure-rtt command to measure the round trip time.
CSCsk91974
Symptom: When you issue the show tech-support sme or the show klm internal isapi_scsi command
after attaching to a module, you may see this error message: cat: write error: Bad address. This
issue does not affect the actual tech-support log.
Workaround: None.
CSCsk73654
Symptom: In certain tape libraries, the tape drives are exported as LUNs. If these target ports are already
a part of a Cisco SME configuration and new tape drives are added as LUNs, the new tape drives will not
be discovered during a Cisco SME tape group or tape device configuration.
Workaround: Perform a rescan at the host level or a flap of the target port to allow Cisco SME to
rediscover these newly added tape drives.
CSCsk43927
Symptom: The following Fabric Manager client components that use SSH and Telnet do not work
well with NAT:
DMM storage job creation
Cisco SAN-OS software upgrade
Zone activation
Workaround: None.
CSCsk90998
Symptom: The signal loss counters in the output of the show interface fcx/y command are not
incremented.