Cisco MDS 9000 Family Release Notes for Cisco MDS NX-OS Release 4.2(1a) (OL-19964-02, September 2009)

Send documentation comments to mdsfeedback-doc@cisco.com
45
Cisco MDS 9000 Family Release Notes for Cisco MDS NX-OS Release 4.2(1a)
OL-19964-02
Related Documentation
Workaround: This issue is resolved.
CSCsz22811
Symptom: Compression throughput on the MSM-18/4 module has been improved.
Workaround: This issue is resolved.
CSCtb80346
Symptom: When an SFP is removed because a port if Administratively Down or Out of Service, a
syslog message should be generated.
Workaround: This issue is resolved.
Open Caveats
CSCta22244
Symptom: On MDS switches running NX-OS Release 4.2(1a), an fctrace command or fcping
command will not show the correct path to the target switch if any of the switches are connected
through an ISL using any of the ports of the following modules:
DS-X9248-48K9: 4/44-Port 8-Gbps Host-Optimized Fibre Channel Switching Module
DS-X9248-96K9: 48-Port 8-Gbps Fibre Channel Switching Module
DS-X9224-96K9: 24-Port 8-Gbps Fibre Channel Switching Module
The output of an fctrace or fcping command will not show any information about the switches
connected through the ports of these modules.
Workaround: None.
CSCsq20408
Symptom: The show startup command displays aspects of the running configuration when SANtap
is configured and/or SANtap objects are created. When a user creates objects such as a CVT or DVT,
the configuration is showing in the running-configuration and in the startup-configuration without
copying the configuration into the startup-configuration.
Workaround: Issue a copy running-config startup-config command whenever you create objects
such as a CVT or DVT so that the running-configuration and startup-configuration are synchronized.
CSCsy37951
Symptom: The Trunking F PortChannels feature is not available in NX-OS Release 4.1(1x);
however, a downgrade from Release 4.1(3a) or later to Release 4.1(1x) is nondisruptive, even when
the Trunking F PortChannels feature is enabled (using the feature fport-channel-trunk command)
while running Release 4.1(3a) or later.
Workaround: If a downgrade to Release 4.1(1x) is performed when the Trunking F PortChannels
feature is enabled, the switch will be in an inconsistent state. You must reload the switch after a
downgrade to Release 4.1(1x).
Related Documentation
The documentation set for NX-OS for the Cisco MDS 9000 Family includes the following documents.
To find a document online, access the following web site:
http://www.cisco.com/en/US/partner/products/ps5989/tsd_products_support_series_home.html