Caveats
Workaround: This issue is resolved.
CSCsq27248
Symptom: If some database processes are shut down uncleanly (for example, the host crashes or a
process is killed) the following message may be seen:
com.cisco.dcbu.lib.rrd.core.RrdException: Bad sample timestamp
1210312407. Last update time was 9221120237041090560, at
least one second step is required
This means that an RRD file has been corrupted.
Workaround: This issue is resolved.
CSCsq40292
Symptom: The Control Virtual Target (CVT) creation fails.
Workaround: This issue is resolved.
CSCsr08325
Symptom: The Fabric Manager web client shows Fabric Events with the next description:
VSAN ... zone activation success, local switch is 00:00:00:00:00:00:00:00
This issue might occur if the enhanced zone mode is configured for a VSAN.
Workaround: This issue is resolved.
CSCsr15094
Symptom: If the KMC response comes back with a failure after 10 seconds, it might get stuck in a
locked state.
Workaround: This issue is resolved.
CSCsq94831
Symptom: Typing the Nexus 5000 switch IP address in the browser address bar shows a download
page which says Cisco Device Manager for MDS 9000 Series
Workaround: This issue is resolved.
CSCsu27719
Symptom: PostgreSQL does not shutdown unless it can close all the connections it has. Usually it
does not shutdown because it has a connection with Fabric Manager Server.
Workaround: This issue is resolved.
CSCsu26064
Symptom: When running Fabric Manager 3.2(3) and SAN-OS 3.2(3), go to Fabric Manager >
Physical Devices Panel > End Devices > Hosts. The panel that displays in the top right showing the
Nx ports does not display all fields for 4GB Qlogic modules. It does not show Model, Firmware or
Driver for 4GB Qlogic cards. 2GB Qlogic modules for same switch and FM, show Model, Firmware
and Driver.
If you look in Device Manager > FC > Name Server > Advanced tab. In the SymbolicNodeName
column you can see HPAE311A FW:v4.00.23 DVR:v9.1.3.16 for the card that does not display
correctly in Fabric Manager.
On the switch, if you enter show fcns data detail command you can see the
symblic-node-name for the missing HBA.
------------------------
VSAN:10 FCID:0x0a0011
------------------------