Chapter 2 System Messages and Recovery Procedures for the Cisco MDS 9000 Family
Error Message FCDOMAIN-3-NVRAMFAILURE: NVRAM open failed.
Explanation
Reading the last assigned run time domain IDs from NVRAM failed.
Recommended Action The domain manager is able to continue without using the NVRAM.
Introduced Cisco MDS SAN-OS Release 1.2(2a).
Error Message FCDOMAIN-3-PORT_SUSPENDED: Response (Cmd Code [hex]) for SWILS [hex]
intended for [chars] is received on [chars].
Explanation
An FC2 SW-ILS response frame has been received on the wrong interface.
Recommended Action Check the configuration of both the interfaces on the local switch; also check
the interfaces on the other side of the corresponding links. Ensure whether the interfaces should all
belong to the same PortChannel.
Introduced Cisco MDS SAN-OS Release 2.1(1a).
Error Message FCDOMAIN-3-SDWRAPBIND_FAILED: Bind to debug server failed.
Explanation The domain manager feature has not been able to contact the debug service. Any
problems occurring in the The domain manager feature will not be logged.
Recommended Action No action is required.
Introduced Cisco MDS SAN-OS Release 2.0(1b).
Error Message FCDOMAIN-3-SDWRAPHISTINIT_FAILED: Initialization of history message
list failed.
Explanation
The domain manager feature has not been able to contact the debug history service. Any
problems occurring in the fcdomain feature will not be logged to this debug history.
Recommended Action No action is required.
Introduced Cisco MDS SAN-OS Release 2.0(1b).
Error Message FCDOMAIN-3-VSAN_MERGE_DETECTED: Merge detected with VSAN [dec]
(Common Fabric Name [chars]).
Explanation
The local VSAN and VSAN [dec] have the same principal switch [chars], hence are
connected in the same logical fabric.
Recommended Action No action is required.
Introduced Cisco MDS SAN-OS Release 3.0(1).