Cisco MDS 9000 Family System Messages Reference (OL-15956-01, April 20078)

Send documentation comments to mdsfeedback-doc@cisco.com
2-204
Cisco MDS 9000 Family System Messages Reference
OL-15956-01
Chapter 2 System Messages and Recovery Procedures for the Cisco MDS 9000 Family
MODULE-6
Error Message MODULE-6-MOD_PURGE_CONFIG: Purging the configuration for module [dec].
Explanation Notification is sent to remove module configurations.
Recommended Action No action is required.
Introduced Cisco MDS SAN-OS Release 3.1(1).
Error Message MODULE-6-MOD_REG_OK: Registration succeeded for module [dec].
Explanation
Module sent a successful registration message.
Recommended Action No action is required.
Introduced Cisco MDS SAN-OS Release 1.2(2a).
NASB Messages
This section contains the Network-Accelerated Serverless Backup (NASB) messages.
NASB-SLOT#-5
Error Message NASB-SLOT#-5-LOG_ERR_TPC_DPP_DEAD: VSAN :[dec] VT pWWN :[chars] DPP
died.
Explanation
The data path processor (DPP) associated with the virtual target failed.
Recommended Action No action is required.
Introduced Cisco MDS SAN-OS Release 2.1(1a).
Error Message NASB-SLOT#-5-LOG_ERR_TPC_VT_ACT_FAILED: VSAN :[dec] VT pWWN :[chars]
VT Activate failed.
Explanation
The activate step for a virtual target failed.
Recommended Action No action is required.
Introduced Cisco MDS SAN-OS Release 2.1(1a).
Error Message NASB-SLOT#-5-LOG_ERR_TPC_VT_CREATE_FAIL: VSAN :[dec] VT pWWN :[chars]
VT and NPort creation FAILED !!!.
Explanation
The virtual target and N port creation failed.
Recommended Action No action is required.
Introduced Cisco MDS SAN-OS Release 2.1(1a).