Cisco MDS 9000 Family System Messages Reference (OL-15956-01, April 20078)

Send documentation comments to mdsfeedback-doc@cisco.com
2-215
Cisco MDS 9000 Family System Messages Reference
OL-15956-01
Chapter 2 System Messages and Recovery Procedures for the Cisco MDS 9000 Family
NVP-SLOT# Messages
This section contains the virtual N port slot (NVP-SLOT#) messages.
NVP-SLOT#-2
Error Message NVP-SLOT#-2-CPP_CATASTROPHIC_ERROR: ERROR: Component ([chars]) caused
critical error please reboot ILC.
Explanation
The listed component caused a critical error.
Recommended Action Restart the line card.
Introduced Cisco MDS SAN-OS Release 2.0(1b).
PLATFORM Messages
This section contains the platform messages.
PLATFORM-0
Error Message PLATFORM-0-CHASSIS_CLKSWITCH: Hardware clock switched to redundant
clock-[dec].
Explanation
Clock module on chassis detected a failure and switched to the redundant clock module.
Recommended Action Enter the show platform internal info command to collect more information
or use a similar Fabric Manager procedure.
Introduced Cisco MDS SAN-OS Release 1.2(2a).
Error Message PLATFORM-0-CHASSIS_CLKSW_MODULE_RESET: Modules reset due to clock
switch.
Explanation
The chassis clock source has been switched and all Generation 1 line cards will be reset.
The system will automatically continue using a redundant clock module.
Recommended Action Replace the failed clock module.
Introduced Cisco MDS SAN-OS Release 3.0(1).
Error Message PLATFORM-0-CHASSIS_CLKSWRESET: Switch reset due to clock switch.
Explanation Chassis clock source has failed and system will be reset. System will automatically start
using the redundant clock module.
Recommended Action Replace the failed clock module during the next maintenance window.
Introduced Cisco MDS SAN-OS Release 1.2(2a).