Cisco MDS 9000 Family System Messages Reference (OL-15956-01, April 20078)

Send documentation comments to mdsfeedback-doc@cisco.com
2-216
Cisco MDS 9000 Family System Messages Reference
OL-15956-01
Chapter 2 System Messages and Recovery Procedures for the Cisco MDS 9000 Family
Error Message PLATFORM-0-FAIL_REMOVED: Fan module removed before [dec] seconds.
Explanation
Fan module was removed. This could lead to temperature alarms.
Recommended Action Replace the fan module immediately.
Introduced Cisco MDS SAN-OS Release 1.2(2a).
Error Message PLATFORM-0-MOD_TEMPMAJALRM: Module [dec] reported major temperature
alarm.
Explanation
Module in the slot exceeded a major temperature threshold.
Recommended Action Enter the show env temperature CLI command or use a similar Fabric
Manager/Device Manager procedure to collect more information.
Introduced Cisco MDS SAN-OS Release 1.2(2a).
Error Message PLATFORM-0-MOD_TEMPRECOVER: Module [dec] recovered from major
temperature alarm. Minor temperature alarm pending.
Explanation
Module recovered from a major temperature threshold. Minor threshold still exceeded.
Recommended Action Enter the show env temperature CLI command or use a similar Fabric
Manager/Device Manager procedure to collect more information.
Introduced Cisco MDS SAN-OS Release 1.2(2a).
Error Message PLATFORM-0-MOD_TEMPSHUTDOWN: Module [dec] powered down due to major
temperature alarm.
Explanation
Module shut down because temperature exceeded major threshold.
Recommended Action Enter show env temperature CLI command or use a similar Fabric
Manager/Device Manager procedure to collect more information.
Introduced Cisco MDS SAN-OS Release 1.2(2a).
Error Message PLATFORM-0-SUP_SPROM_ERROR: Unable to read SPROM for Sup in slot [dec].
Explanation
The supervisor in the slot named was not able to read its SPROM.
Recommended Action No action is required.
Introduced Cisco MDS SAN-OS Release 3.0(1).
Error Message PLATFORM-0-SUP_WRONGSLOTNUM: Supervisor powered up in WRONG SLOT:[dec]
(Serial number [chars]).
Explanation
The supervisor is coming up in wrong slot.
Recommended Action No action is required.
Introduced Cisco MDS SAN-OS Release 3.0(1).