Cisco MDS 9000 Family System Messages Reference (OL-15956-01, April 20078)

Send documentation comments to mdsfeedback-doc@cisco.com
2-218
Cisco MDS 9000 Family System Messages Reference
OL-15956-01
Chapter 2 System Messages and Recovery Procedures for the Cisco MDS 9000 Family
Introduced Cisco MDS SAN-OS Release 1.2(2a).
Error Message PLATFORM-0-XBAR_CARD_CLK_FAIL: Xbar card in slot:[dec] (Serial number
[chars]) encountered clock failure.
Explanation
The xbar in the slot named encountered clock failure.
Recommended Action No action is required.
Introduced Cisco MDS SAN-OS Release 3.0(1).
Error Message PLATFORM-0-XBAR_CARD_INCOMPAT_CHASSIS: Xbar card in slot:[dec] (Part
number [chars]) Incompatible with backplane chassis Part Num:[chars].
Explanation
The xbar in the slot named is incompatible with backplane chassis.
Recommended Action No action is required.
Introduced Cisco MDS SAN-OS Release 3.0(1).
Error Message PLATFORM-0-XBAR_WRONGSLOTNUM: Xbar powered up in WRONG SLOT:[dec]
(Serial number [chars]).
Explanation
The xbar in the slot named powered up in wrong slot.
Recommended Action No action is required.
Introduced Cisco MDS SAN-OS Release 3.0(1).
PLATFORM-1
Error Message PLATFORM-1-CASA_FAN_FAIL: Fan module [dec] Failed.
Explanation
Fan module failed and needs to be replaced. This can lead to overheating and
temperature alarms.
Recommended Action Enter the show platform internal info CLI command or use a similar Fabric
Manager/Device Manager procedure to collect more information.
Introduced Cisco MDS SAN-OS Release 1.3(4a).
Error Message PLATFORM-1-FAN_FAIL: Fan module Failed.
Explanation
Fan module failed and needs to be replaced. This can lead to overheating and
temperature alarms.
Recommended Action Enter the show platform internal info CLI command or use a similar Fabric
Manager/Device Manager procedure to collect more information.
Introduced Cisco MDS SAN-OS Release 1.2(2a).