Error Message PLATFORM-2-PFM_LC_BOOT_DEV_ABSENT: No bootflash found in Module
[dec].
Explanation No bootflash found.
Recommended Action Put bootflash in the module and try again.
Introduced Cisco MDS SAN-OS Release 1.2(2a).
Error Message PLATFORM-2-PFM_LC_BOOT_DEV_FAIL: Bootflash access error in Module
[dec].
Explanation Bad bootflash/corrupted file system.
Recommended Action Try to put in a known good bootflash in the module and try again.
Error Message PLATFORM-2-PFM_LC_BOOT_DEV_FAIL: BAD Bootflash found in Module [dec].
Explanation Bad bootflash found.
Recommended Action Put a good bootflash in the module and try again.
Introduced Cisco MDS SAN-OS Release 1.2(2a).
Error Message PLATFORM-2-PFM_LC_MOD_POWERED_DOWN: Module [dec] Powered Down. Module
is not supported in this chassis. (Chassis Incompatible card).
Explanation
Module has been powered down because the card is not supported in this chassis.
Recommended Action Use the show module CLI command to see the power down reason, or use a
similar Fabric Manager procedure.'
Introduced Cisco MDS SAN-OS Release 3.0(1).
Error Message PLATFORM-2-PFM_NETBOOT_DISABLE: Netboot for supervisor module in slot
[dec] is disabled due to incompatible platform.
Explanation
Standby supervisor failed to power up.
Recommended Action Try to replace the standby supervisor.
Introduced Cisco MDS SAN-OS Release 3.0(1).
Error Message PLATFORM-2-PFM_LC_NETBOOT_FAIL: Netboot for Module [dec] failed.
Explanation
Netboot failed.
Recommended Action Replace the BIOS in the module.
Introduced Cisco MDS SAN-OS Release 1.2(2a).