Cisco MDS 9000 Family System Messages Reference (OL-15956-01, April 20078)

Send documentation comments to mdsfeedback-doc@cisco.com
2-225
Cisco MDS 9000 Family System Messages Reference
OL-15956-01
Chapter 2 System Messages and Recovery Procedures for the Cisco MDS 9000 Family
Error Message PLATFORM-2-PS_CAPACITY_DIFFER: Detected power supplies with differing
capacity. It is recommended to have same capacity for both powersupplies otherwise
it may cause service disruptions.
Explanation
Detected a power supply that has a different capacity than an the other power supply.
Recommended Action Refer tot he Cisco MDS 9000 Family CLI Configuration Guide for information
on increasing or decreasing power supply capacity and configuring power supplies. Use the show
environment power and show platform internal info to collect more information.
Introduced Cisco MDS SAN-OS Release 3.0(1).
Error Message PLATFORM-2-PS_DETECT: Power supply [dec] detected but shutdown (Serial
number [chars]).
Explanation
Power Supply is detected but has been shut down.
Recommended Action Use the CLI commands show environment power and show platform
internal info to collect more information, or use similar Fabric Manager procedures.
Introduced Cisco MDS SAN-OS Release 3.0(1).
Error Message PLATFORM-2-PS_FAIL: Power supply [dec] failed or shutdown (Serial No.
[chars]).
Explanation
Power supply failed or has been shut down.
Recommended Action Enter the show environment power and show platform internal info CLI
command or use a similar Fabric Manager or Device Manager procedure to collect more
information. See the power supply documentation in the relevant hardware installation guide to learn
more on increasing or decreasing power supply capacity and configuring power supplies.
Introduced Cisco MDS SAN-OS Release 1.2(2a).
Error Message PLATFORM-2-PS_FANFAIL: Fan in Power supply [dec] failed.
Explanation
Fan module in the named power supply has failed.
Recommended Action Enter the show environment power and show platform internal info CLI
command or use a similar Fabric Manager/Device Manager procedure to collect more information.
Introduced Cisco MDS SAN-OS Release 1.3(1).
Error Message PLATFORM-2-PS_FANOK: Fan in Power supply [dec] ok.
Explanation Fan module in the named power supply is operating.
Recommended Action No action is required.
Introduced Cisco MDS SAN-OS Release 3.0(1).