Cisco MDS 9000 Family System Messages Reference (OL-15956-01, April 20078)

Send documentation comments to mdsfeedback-doc@cisco.com
2-228
Cisco MDS 9000 Family System Messages Reference
OL-15956-01
Chapter 2 System Messages and Recovery Procedures for the Cisco MDS 9000 Family
Error Message PLATFORM-3-MOD_PWRIDPROMFAIL: Module [dec] failed to power up due to
idprom read error.
Explanation The module cannot be powered up because of an IDPROM read error.
Recommended Action Enter the show platform internal all module [dec] and show module
internal all module [dec] show sprom module [dec][dec] CLI commands or use similar Fabric
Manager/Device Manager procedures to collect more information.
Introduced Cisco MDS SAN-OS Release 1.2(2a).
Error Message PLATFORM-3-SYS_IDPROMBAD: Chassis idprom [dec] data invalid.
Explanation
The chassis IDPROM contains invalid data.
Recommended Action Enter the show sprom module [dec] CLI command or use a similar Fabric
Manager/Device Manager procedure to read module idprom contents and collect more information.
Introduced Cisco MDS SAN-OS Release 1.2(2a).
Error Message PLATFORM-3-XBAR_PWRFAIL: Xbar [dec] failed to power up (Serial number
[chars]).
Explanation
The named xbar in the slot failed to power up.
Recommended Action Use the show platform internal all module [decimaldigit] CLI command to
collect more information or use a similar Fabric Manager procedure.
Introduced Cisco MDS SAN-OS Release 3.0(1).
Error Message PLATFORM-3-XBAR_PWRIDPROMFAIL: Xbar [dec] failed to power up due to
IDPROM read error.
Explanation
The xbar named cannot be powered up because of an IDPROM read error.
Recommended Action Use the CLI commands show platform internal all module [decimaldigit]
and show module internal all module [decimaldigit] and show sprom xbar [dec] [dec] to read
module IDPROM contents to collect more information (or use a similar Fabric Manager procedure).
Introduced Cisco MDS SAN-OS Release 3.0(1).
PLATFORM-4
Error Message PLATFORM-4-MOD_TEMPFAIL: [chars] temperature sensor [dec] failed.
Explanation
The module in the slot named contains a faulty temperature sensor.
Recommended Action Use the show env temperature CLI command to collect more information or
use a similar Fabric Manager procedure.
Introduced Cisco MDS SAN-OS Release 3.0(1).