Cisco MDS 9000 Family System Messages Reference (OL-15956-01, April 20078)

Send documentation comments to mdsfeedback-doc@cisco.com
2-231
Cisco MDS 9000 Family System Messages Reference
OL-15956-01
Chapter 2 System Messages and Recovery Procedures for the Cisco MDS 9000 Family
Error Message PLATFORM-5-PS_FANOK: Fan in Power supply [dec] ok.
Explanation
Fan module in the named power supply is operating normally.
Recommended Action No action is required.
Introduced Cisco MDS SAN-OS Release 1.3(1).
Error Message PLATFORM-5-PS_OK: Power supply [dec] ok (Serial No. [chars]).
Explanation Power supply is operating normally.
Recommended Action No action is required.
Introduced Cisco MDS SAN-OS Release 1.2(2a).
Error Message PLATFORM-5-PS_REMOVE: Power supply [dec] removed (Serial No.
[chars]).
Explanation
Power supply has been removed.
Recommended Action No action is required.
Introduced Cisco MDS SAN-OS Release 1.2(2a).
Error Message PLATFORM-5-SYS_SHUTDOWN: System shutdown in [dec] seconds due to major
temperature alarm.
Explanation
System shut down in seconds because the temperature exceeded a major threshold.
Recommended Action Enter the show env temperature CLI command or use a similar Fabric
Manager/Device Manager procedure to collect more information.
Introduced Cisco MDS SAN-OS Release 1.2(2a).
Error Message PLATFORM-5-XBAR_DETECT: Xbar [dec] detected (Serial number [chars]).
Explanation
A new xbar in the slot named has been detected.
Recommended Action No action is required.
Introduced Cisco MDS SAN-OS Release 3.0(1).
Error Message PLATFORM-5-XBAR_PWRDN: Xbar [dec] powered down (Serial number
[chars]).
Explanation
The xbar in the slot named is powered down.
Recommended Action Perform a
showmodulexbar','showplatforminternalallmodule[decimaldigit]'and'showmoduleinternalallmodul
e[decimaldigit]'tocollectmoreinformationifyoususpectmodulehasbeenpowereddownduetoerrors.'
Introduced Cisco MDS SAN-OS Release 3.0(1).