Cisco MDS 9000 Family System Messages Reference (OL-15956-01, April 20078)

Send documentation comments to mdsfeedback-doc@cisco.com
2-232
Cisco MDS 9000 Family System Messages Reference
OL-15956-01
Chapter 2 System Messages and Recovery Procedures for the Cisco MDS 9000 Family
Error Message PLATFORM-5-XBAR_PWRUP: Xbar [dec] powered up (Serial number [chars]).
Explanation
The xbar in the slot named is powered up.
Recommended Action No action is required.
Introduced Cisco MDS SAN-OS Release 3.0(1).
Error Message PLATFORM-5-XBAR_REMOVE: Xbar [dec] removed (Serial number [chars]).
Explanation The xbar in the slot named has been removed.
Recommended Action No action is required.
Introduced Cisco MDS SAN-OS Release 3.0(1).
PLATFORM-7
Error Message PLATFORM-7-PFM_CLOCK_UPD_FAIL: Clock update failed due to
context-switch delay of [dec] msec.
Explanation System will shut down in seconds because of a clock update failure.
Recommended Action Enter the show env temperature CLI command or use a similar Fabric
Manager/Device Manager procedure to collect more information.
Introduced Cisco MDS SAN-OS Release 1.2(2a).
PLOG Messages
This section contains the persistent logger (PLOG) messages.
PLOG-4
Error Message PLOG-4-PLOG_LC_EXIT: Persistent Logger encountered an error [dec].
Explanation Persistent Logger encountered an error.
Recommended Action No action is required.
Introduced Cisco MDS SAN-OS Release 3.0(1).
PLOG_SUP Messages
This section contains the persistent logger (PLOG_SUP) messages.