Cisco MDS 9000 Family System Messages Reference (OL-15956-01, April 20078)

Send documentation comments to mdsfeedback-doc@cisco.com
2-361
Cisco MDS 9000 Family System Messages Reference
OL-15956-01
Chapter 2 System Messages and Recovery Procedures for the Cisco MDS 9000 Family
Error Message SVC_BATTERY-SLOT#-2-CONDITIONING_DISABLED: Temperature outside
permitted range for battery conditioning (5C-40C).
Explanation The temperature of the line card is not within the range to permit battery conditioning.
Recommended Action Make sure the temperature of the line card is between 5 and 40
0
C.
Error Message SVC_BATTERY-SLOT#-2-DISCHARGING_FAILURE: Discharging failure in
battery [dec] ([hex]).
Explanation
The module encountered failures while discharging a battery.
Recommended Action Replace the battery. If you purchased Cisco support through a Cisco reseller,
contact the reseller directly. If you purchased support directly from Cisco Systems, contact Cisco
Technical Support.
Introduced Cisco MDS SAN-OS Release 1.3(4a).
SVC_BATTERY-SLOT#-4
Error Message SVC_BATTERY-SLOT#-4-BATTERY_CAPACITY_LOW: Battery capacity is below
the required threshold.
Explanation
The battery is lower than the required threshold.
Recommended Action Make sure the temperature is within the range to allow charging.
Introduced Cisco MDS SAN-OS Release 1.3(1).
SVC_BATTERY-SLOT#-6
Error Message SVC_BATTERY-SLOT#-6-BATTERY_CAPACITY_OK: Battery capacity is above
the required threshold.
Explanation
The battery is above the required threshold.
Recommended Action No action is required.
Introduced Cisco MDS SAN-OS Release 1.3(1).
Error Message SVC_BATTERY-SLOT#-6-CONDITIONING_CANCELLED: Temperature outside
permitted range for battery conditioning (5C-40C). Battery [dec] conditioning
cancelled.
Explanation
The temperature of the module is not within the range to permit battery conditioning.
Recommended Action Make sure the temperature of the line card is between 5 and 40
0
C.
Introduced Cisco MDS SAN-OS Release 1.3(1).