Cisco MDS 9000 Family System Messages Reference (OL-15956-01, April 20078)

Send documentation comments to mdsfeedback-doc@cisco.com
2-367
Cisco MDS 9000 Family System Messages Reference
OL-15956-01
Chapter 2 System Messages and Recovery Procedures for the Cisco MDS 9000 Family
Error Message SYSMGR-2-FORMAT_FAILURE_SUP_RESET: Failure to format a partition
successfully causing sup to reset.
Explanation The partition used to store nonvolatile persistent storage service (PSS) files could not
be formatted successfully. The supervisor will be reset.
Recommended Action If the problem persists, contact customer support. If you purchased Cisco
support through a Cisco reseller, contact the reseller directly. If you purchased support directly from
Cisco Systems, contact Cisco Technical Support.
Introduced Cisco MDS SAN-OS Release 1.3(1).
Error Message SYSMGR-2-GSYNC_ABORT: Global sync aborted by signal.
Explanation
The initial synchronization of the services was terminated. The synchronization will be
attempted again later.
Recommended Action Enter the reload module CLI command or use an equivalent Fabric
Manager/Device Manager procedure to reset the standby supervisor.
Introduced Cisco MDS SAN-OS Release 1.2(2a).
Error Message SYSMGR-2-GSYNC_GET_TIMEOUT: Request for global sync for UUID [hex]
not completed in specified time.
Explanation
Service failed to complete global sync in specified time. The standby will no longer act
as a high availability standby.
Recommended Action If the problem persists, contact customer support. If you purchased Cisco
support through a Cisco reseller, contact the reseller directly. If you purchased support directly from
Cisco Systems, contact Cisco Technical Support.
Introduced Cisco MDS SAN-OS Release 1.3(1).
Error Message SYSMGR-2-GSYNC_READY_SRVFAILED: Service "[chars]" on standby
supervisor failed to restore its snapshot (error-id [hex]).
Explanation
The initial synchronization of service failed.
Recommended Action If you purchased Cisco support through a Cisco reseller, contact the reseller
directly. If you purchased support directly from Cisco Systems, contact Cisco Technical Support.
Introduced Cisco MDS SAN-OS Release 1.3(1).
Error Message SYSMGR-2-GSYNC_SNAPSHOT_SRVFAILED: Service "[chars]" on active
supervisor failed to store its snapshot (error-id [hex]).
Explanation
The initial synchronization of service failed.
Recommended Action If you purchased Cisco support through a Cisco reseller, contact the reseller
directly. If you purchased support directly from Cisco Systems, contact Cisco Technical Support.
Introduced Cisco MDS SAN-OS Release 1.2(2a).