Chapter 2 System Messages and Recovery Procedures for the Cisco MDS 9000 Family
Error Message VFC-6-STARTING: deamon started.
Explanation
The virtual Fibre Channel (VFC) daemon successfully started.
Recommended Action No action is required.
Introduced Cisco MDS SAN-OS Release 2.0(1b).
VHBAD Messages
This section contains the virtual host bus adapter daemon (VHBAD) messages.
VHBAD-2
Error Message VHBAD-2-PROC_ADD_NPORT_FAIL: Failed to set local nport with SCSI
target driver error: [hex].
Explanation
SCSI target process tried to add N port with its peer kernel driver. No SCSI discovery
can be performed.
Recommended Action Enter the show SCSI target internal driver CLI command or use a similar
Fabric Manager/Device Manager procedure to collect more information.
Introduced Cisco MDS SAN-OS Release 1.2(2a).
Error Message VHBAD-2-PROC_OPEN_VHBA_DEVICE_FAIL: Failed to communicate with SCSI
target driver error: [hex].
Explanation
SCSI target process failed to communicate with its peer kernel driver. No SCSI
discovery can be performed.
Recommended Action Enter the show SCSI target internal driver CLI command or use a similar
Fabric Manager/Device Manager procedure to collect more information.
Introduced Cisco MDS SAN-OS Release 1.2(2a).
Error Message VHBAD-2-PROC_SET_SCSI_INDEX_FAIL: Failed to set SCSI index SCSI
target driver error: [hex].
Explanation
SCSI target process failed to set SCSI index with its peer kernel driver. No SCSI
discovery can be performed.
Recommended Action Enter the show SCSI target internal driver CLI command or use a similar
Fabric Manager/Device Manager procedure to collect more information.