Cisco MDS 9000 Family System Messages Reference (OL-15956-01, April 20078)

Send documentation comments to mdsfeedback-doc@cisco.com
2-462
Cisco MDS 9000 Family System Messages Reference
OL-15956-01
Chapter 2 System Messages and Recovery Procedures for the Cisco MDS 9000 Family
Error Message XBAR-5-XBAR_SET_ACCESS_FAIL: Slot [dec] reported failure acquiring
[chars] xbar access return_code [hex] ([chars]).
Explanation The supervisor has experienced an xbar access failure.
Recommended Action No action is required.
Introduced Cisco MDS SAN-OS Release 3.0(1).
Error Message XBAR-5-XBAR_STATUS_REPORT: Module [dec] reported status for component
[dec] code [hex].
Explanation An error status has been reported. If an error is on a supervisor module, the supervisor
module is rebooted. In case of dual supervisors, a switchover occurs. If an error is on another
module, the module is power cycled.
Recommended Action No action is required.
Introduced Cisco MDS SAN-OS Release 1.2(2a).
Error Message XBAR-5-XBAR_SW_INIT_FAIL: Xbar [[dec].[dec]] reported failure durinig
sw intialization return_code [hex] ([chars]).
Explanation The supervisor has experienced an xbar setup failure.
Recommended Action No action is required.
Introduced Cisco MDS SAN-OS Release 3.0(1).
Error Message ZONE-6-ZS_INVALID_MEMBER: Invalid member [dec] [chars].
Explanation Invalid member type [dec] [chars] received from the API call.
Recommended Action Perform a manual build fabric using fcdomain's interface if you would like to
remove the unused virtual domain(s) from the fcdomain list.
Introduced Cisco MDS SAN-OS Release 3.0(1).
XBAR_CLIENT Messages
This section contains the crossbar client (XBAR_CLIENT) messages.
XBAR_CLIENT-2
Error Message XBAR_CLIENT-2-MEM_FULL: Memory allocation failed.
Explanation
The crossbar client process has failed to allocate memory.
Recommended Action Enter the show xbar-client event-history command or use a similar Fabric
Manager/Device manager procedure to collect more information.
Introduced Cisco MDS SAN-OS Release 1.2(2a).