Cisco Nexus 5000 Series Switch CLI Software Configuration Guide, NX-OS 4.0(1a)N1 (OL-16597-01, January 2009)

Send feedback to nx5000-docfeedback@cisco.com
32-9
Cisco Nexus 5000 Series Switch CLI Software Configuration Guide
OL-16597-01
Chapter 32 Configuring Fibre Channel Interfaces
Configuring Fibre Channel Interfaces
To configure a range of interfaces, perform this task:
Setting the Interface Administrative State
To gracefully shut down an interface, perform this task:
To enable traffic flow, perform this task:
Configuring Interface Modes
To configure the interface mode, perform this task:
Command Purpose
Step 1
switch# configuration terminal
Enters configuration mode.
Step 2
switch(config)# interface fc
slot/port - port [ , fc slot/port -
port ]
or
switch(config)# interface vfc vfc-id
- vfc-id [, vfc vfc-id - vfc-id ]
Selects the range of Fibre Channel interfaces and enters
interface configuration mode.
Command Purpose
Step 1
switch# configuration terminal
Enters configuration mode.
Step 2
switch(config)# interface {fc
slot/port}|{vfc vfc-id}
Selects a Fibre Channel interface and enters interface
configuration mode.
Step 3
switch(config-if)# shutdown
Gracefully shuts down the interface and administratively
disables traffic flow (default).
Command Purpose
Step 1
switch# configuration terminal
Enters configuration mode.
Step 2
switch(config)# interface {fc
slot/port}|{vfc vfc-id}
Selects a Fibre Channel interface and enters interface
configuration mode.
Step 3
switch(config-if)# no shutdown
Enables traffic flow to administratively allow traffic
when the no prefix is used (provided the operational state
is up).
A virtual Fibre Channel interface becomes operational if
the bound Ethernet interface is operational and its STP
port state is active.
Command Purpose
Step 1
switch# configuration terminal
Enters configuration mode.
Step 2
switch(config)# interface {fc
slot/port}|{vfc vfc-id}
Selects a Fibre Channel interface and enters interface
configuration mode.