Cisco Nexus 5000 Series Switch CLI Software Configuration Guide, NX-OS 4.0(1a)N1 (OL-16597-01, January 2009)

Send feedback to nx5000-docfeedback@cisco.com
33-17
Cisco Nexus 5000 Series Switch CLI Software Configuration Guide
OL-16597-01
Chapter 33 Configuring Domain Parameters
FC IDs
switch(config)# end
switch#
Step 5 Assign a new FC ID with a different area allocation. In this example, we replace 77 with ee.
switch# configuration terminal
switch(config)# fcdomain fcid database
switch(config-fcid-db)# vsan 3 wwn 50:05:08:b2:00:71:c8:c2 fcid 0x6fee00 area
Step 6 Enable the HBA interface in the Cisco Nexus 5000 Series switch.
switch# configuration terminal
switch(config)# interface vfc20/1
switch(config-if)# no shutdown
switch(config-if)# end
switch#
Step 7 Verify the pWWN ID of the HBA by using the show flogi database command.
switch# show flogi database
------------------------------------------------------------------------------------------
INTERFACE VSAN FCID PORT NAME NODE NAME
------------------------------------------------------------------------------------------
vfc20/1 3 0x6fee00 50:05:08:b2:00:71:c8:c2 50:05:08:b2:00:71:c8:c0
fc2/3 3 0x6f7704 50:06:0e:80:03:29:61:0f 50:06:0e:80:03:29:61:0f
Note Both FC IDs now have different area assignments.
About Persistent FC ID Selective Purging
Persistent FC IDs can be purged selectively. Static entries and FC IDs currently in use cannot be deleted.
Table 33-1 identifies the FC ID entries that are deleted or retained when persistent FC IDs are purged.
Table 33-1 Purged FC IDs
Persistent FC ID state Persistent Usage State Action
Static In use Not deleted
Static Not in use Not deleted
Dynamic In use Not deleted
Dynamic Not in use Deleted