Cisco Nexus 5000 Series Switch CLI Software Configuration Guide, NX-OS 4.0(1a)N1 (OL-16597-01, January 2009)

Send feedback to nx5000-docfeedback@cisco.com
43-13
Cisco Nexus 5000 Series Switch CLI Software Configuration Guide
OL-16597-01
Chapter 43 Advanced Fibre Channel Features and Concepts
Switch Interoperability
cisco Nexus5020 Chassis ("40x10GE/Supervisor")
Intel(R) Celeron(R) M CPU with 2074308 kB of memory.
Processor Board ID JAB120900PJ
Device name: d15-switch-5
bootflash: 1003520 kB
Kernel uptime is 0 day(s), 1 hour(s), 29 minute(s), 55 second(s)
Last reset at 510130 usecs after Wed Nov 26 18:12:23 2008
Reason: Reset Requested by CLI command reload
System version: 4.0(1a)N1(1)
Service:
plugin
Core Plugin, Ethernet Plugin
Step 2 Verify if the interface states are as required by your configuration.
switch# show int brief
-------------------------------------------------------------------------------
Interface Vsan Admin Admin Status SFP Oper Oper Port
Mode Trunk Mode Speed Channel
Mode (Gbps)
-------------------------------------------------------------------------------
fc3/1 1 E on trunking swl TE 2 --
fc3/2 1 auto on sfpAbsent -- -- --
fc3/3 1 E on trunking swl TE 2 --
fc3/4 1 auto on sfpAbsent -- -- --
fc3/5 1 auto auto notConnected swl -- --
fc3/6 1 auto on sfpAbsent -- -- --
fc3/7 1 auto auto sfpAbsent -- -- --
fc3/8 1 auto auto sfpAbsent -- -- --
Step 3 Verify if you are running the desired configuration.
switch# show run
Building Configuration...
interface fc2/1
no shutdown
interface fc2/2
no shutdown
interface fc2/3
interface fc2/4
<snip>
interface mgmt0
ip address 6.1.1.96 255.255.255.0
switchport encap default
no shutdown
vsan database
vsan 1 interop
boot system bootflash:/nx5000-system-23e.bin
boot kickstart bootflash:/nx5000-kickstart-23e.bin
callhome
fcdomain domain 100 preferred vsan 1