Cisco Nexus 5000 Series Command Reference Release 4.0(1a)N2(1) (OL-16599-01, March 2009)

Send comments to nx5000-docfeedback@cisco.com
8-65
Cisco Nexus 5000 Series Command Reference
OL-16599-01
Chapter 8 Fibre Channel Commands
fcs plat-check-global
fcs plat-check-global
To enable FCS platform and node-name checking fabric wide, use the fcs plat-check-global command.
To disable this feature, use the no form of the command.
fcs plat-check-global vsan vsan-id
no fcs plat-check-global vsan vsan-id
Syntax Description
Command Default None
Command Modes Configuration mode
Command History
Examples The following example shows how to enable FCS platform and node-name checking fabric wide:
switch(config)# fcs plat-check-global vsan 2
Related Commands
vsan vsan-id Specifies the VSAN ID for platform checking, which is from 1 to 4096.
Release Modification
4.0(0)N1(1a) This command was introduced.
Command Description
show fcs Displays fabric configuration server information.