fspf retransmit-interval
fspf retransmit-interval
To specify the time after which an unacknowledged link state update should be transmitted on the
interface, use the fspf retransmit-interval command. To revert to the default value, use the no form of
the command.
fspf retransmit-interval seconds vsan vsan-id
no spf retransmit-interval seconds vsan vsan-id
Syntax Description
Command Default 5 seconds.
Command Modes Interface configuration mode
Command History
Usage Guidelines This command is not applicable to virtual Fibre Channel interfaces. This value must be the same in the
ports at both ends of the ISL.
Examples The following example specifies a retransmit interval of 6 seconds after which an unacknowledged link
state update should be transmitted on the interface for VSAN 1:
switch(config)# interface fc 2/1
switch(config-if)# fspf retransmit-interval 6 vsan 1
Related Commands
seconds Specifies FSPF retransmit interval in seconds. The range is
1 to 65535.
vsan vsan-id Specifies a VSAN ID. The range is 1 to 4093.
Release Modification
4.0(0)N1(1a) This command was introduced.
Command Description
show fspf interface Displays information for each selected interface.