Cisco Nexus 5000 Series Command Reference Release 4.0(1a)N2(1) (OL-16599-01, March 2009)

Send comments to nx5000-docfeedback@cisco.com
8-126
Cisco Nexus 5000 Series Command Reference
OL-16599-01
Chapter 8 Fibre Channel Commands
rscn event-tov
rscn event-tov
To configure an event timeout value for a Registered State Change Notification (RSCN) on a specified
VSAN, use the rscn event-tov command. To cancel the event timeout value and restore the default value,
use the no form of the command.
rscn event-tov timeout vsan vsan-id
no rscn event-tov timeout vsan vsan-id
Syntax Description
Command Default The default timeout values are 2000 milliseconds for Fibre Channel VSANs.
Command Modes Configuration mode
Command History
Usage Guidelines Before changing the timeout value, you must enable RSCN configuration distribution using the rscn
distribute command.
The RSCN timer is registered with Cisco Fabric Services (CFS) during initialization and switchover.
Examples The following example configures an RSCN event timeout value on VSAN 1:
switch(config)# rscn event-tov 20 vsan 1
Related Commands
timeout Specifies an event timeout value in milliseconds. The range is 0 to 2000.
vsan vsan-id Specifies a VSAN where the RSCN event timer should be used. The ID of
the VSAN is from 1 to 4093.
Release Modification
4.0(0)N1(1a) This command was introduced.
Command Description
rscn abort Cancels a pending RSCN configuration on a specified VSAN.
rscn commit Applies a pending RSCN configuration.
rscn distribute Enables distribution of an RSCN configuration.
clear rscn session Clears the RSCN session for a specified VSAN.
show rscn Displays RSCN configuration information.