Table 2-33 Calibration/Cleaning menu (continued)
First level Second level Values Description
Full Calibration   Start The product automatically
calibrates itself at various times.
However, you can calibrate the
product immediately if you see
problems with print quality. Use
this feature to perform a full
calibration, which can take up to
three minutes. Use this
calibration if the color layers
seem to be shifted on the page.
Before calibrating the product,
make sure that the Ready
indicator displays on the control-
panel display. If a job is in
progress, the calibration occurs
when that job is complete.
Delay Calibration at Wake/
Power On
  Disabled
Enabled*
Controls the timing of power-on
calibration when the product
wakes up or is turned on.
Wake: Select if you are not
using the feature and want to
print jobs immediately when the
product wakes up or is turned
on, before calibration begins.
No option: The product will
calibrate immediately when it
wakes up or is turned on. The
product will not print any jobs
until it finishes calibrating.
Yes: Enables the product that is
asleep to accept print jobs
before it calibrates. It might start
calibrating before it has printed
all the jobs it has received. This
option allows quicker printing
when coming out of sleep mode
or when you turn the product on,
but print quality might be
reduced.
NOTE: For the best results,
allow the product to calibrate
before printing. Print jobs
performed before calibration
might not be of the highest
quality.
Calibrate Scanner  Touch Next to calibrate the
device scanner. Messages on the
control panel display will lead
you through the calibration
process.
246 Chapter 2 Solve problems ENWW