User Guide

55.01.06 (event code): NVRAM memory data error warning
55.02.06 (event code): NVRAM memory access error warning
Recommended action
1. Turn the product off and then on.
2. Perform an engine test.
3. Check the FFC connector (J105) on the DC controller.
4. If the error persists, replace the DC controller PCA.
55.XX.YY DC controller error To continue turn off then on
Description
The communication link between the formatter and DC controller was lost.
55.00.00: Internal communication error
55.00.01: DC controller memory error
55.00.03: DC controller no engine response
55.00.04: DC controller communications timeout
Recommended action
1. Turn the product off and then on.
2. Perform an engine test.
3. Check the FFC connector (J105) on the DC controller.
4. If the error persists, replace the DC controller.
56.00.01 Illegal Input Printer Error To continue turn off then on
Description
The product experienced an illegal input.
Recommended action
1. Turn the product off and then on.
2. Remove any third-party hardware.
3. Attempt the remote firmware update again.
4. If the error persists, replace the DC controller.
286 Chapter 2 Solve problems ENWW