Reference Guide
Rated Line Frequency 50-60 Hz 50-60 Hz
Power Output 300 W 300 W
Rated Input Current (maximum)
1
Standard PS
80 Plus PS
8A @ 100 VAC
4A @ 100VAC
4A @ 200 VAC
2A @ 200VAC
1
The standard power supply utilizes a passive power factor corrected power supply. The power factor correction is present in
the 230V operating mode only. This allows the system to pass the CE mark requirements for use in the countries of the
European Union. This supply requires the use of an input voltage range select switch. The 80 Plus power supply utilizes an
active power factor corrected power supply. This allows the system to pass the CE mark requirements for use in the countries
of the European Union. The active power factor corrected power supply also has the added benefit of not requiring an input
voltage range select switch.
Table A-1 Specifications (continued)
42 Appendix A Specifications ENWW