HP ProLiant Cluster HA/F500 for Enterprise Virtual Array Enhanced DT Supplement Guide
Cluster Installation
Table 2-1: CA Restrictions
continued
Restriction Comment
Each storage system can have a relationship
with one remote storage system.
HSG controllers may be present on the SAN but
cannot interoperate with HSV controllers.
The HSG and HSV controllers must be in
different management zones.
One snapshot or Snapclone allowed per Vdisk. Can be on either the source or destination.
A Continuous Access EVA management zone is
limited to a specified number of large or small
storage systems, depending on distances.
Refer to Table 15 in the HP StorageWorks
Continuous Access EVA Design Reference
Guide for distance limitations.
Up to 10 infrastructure switches per fabric Seven hops are allowed; three per site and one
as the intersite link.
Up to 10 high availability switches per fabric Three hops are allowed; one per site and one
as the intersite link.
Qualified operating systems:
•
Windows Server 2003
•
Windows 2000, Enterprise Edition
•
Windows NT 4.0
For the supported versions of these operating
systems, refer to
http://h18006.www1.hp.com/products/storage/
software/conaccesseva/index.html
HP ProLiant Cluster HA/F500 for Enterprise Virtual Array Enhanced DT Supplement Guide 2-3
HP CONFIDENTIAL
Writer: Bill Akers File Name: c-ch2 Cluster Installation
Codename: 49ers III Part Number: 339223-001 Last Saved On: 5/29/03 2:22 PM