HP ProLiant Cluster HA/F500 for MA8000 Enhanced DT Supplement Guide

Cluster Installation
5. Be sure that the Fibre Channel switches are powered up but not cabled.
6. Power on the storage subsystems. (This refers to RA8000/ESA12000 storage
subsystems.)
NOTE: The controllers will boot when the storage subsystems are powered up if the
PCMCIA program cards are already installed. If there are no cards in the controller slots,
insert them now, and press the Reset button. Refer to the StorageWorks HSG80 Array
Controller ACS maintenance and service guide for complete instructions on properly
seating the controller cards.
7. Establish a local connection to the controller. Refer to the StorageWorks HSG80
Array Controller ACS maintenance and service guide for instructions.
8. Verify that all controllers are turned on and functional by looking for the
CLI prompt on the maintenance port terminal.
NOTE: All operations can be conducted from either controller.