HP ProLiant Cluster HA/F500 for MA8000 Enhanced DT Supplement Guide
Cluster Installation
9. Enter the following command:
SHOW THIS_CONTROLLER
The display will be similar to Figure 2-2.
Controller:
HSG80 ZG8nnnnnnn Software V85P, Hardware E03
NODE_ID = nnnn-nnnn-nnnn-nnnn
ALLOCATION_CLASS = 0
SCSI_VERSION = SCSI-2
Not configured for dual-redundancy
Controller misconfigured – other controller present
Device Port SCSI address 7
Time: NOT SET
Command Console LUN is disabled
Host PORT_1:
Reported PORT_ID = nnnn-nnnn-nnnn-nnnn
PORT_1_TOPOLOGY = OFFLINE (offline)
Host PORT_2:
Reported PORT_ID = nnnn-nnnn-nnnn-nnnn
PORT_2_TOPOLOGY = OFFLINE (offline)
NOREMOTE_COPY
Cache:
512 megabyte write cache, version 0012
Cache is GOOD
No unflushed data in cache
CACHE_FLUSH_TIMER = DEFAULT (10 seconds)
Mirrored Cache:
Not enabled
Battery:
FULLY CHARGED
Expires:
NOCACHE_UPS
Controller misconfigured. Type SHOW THIS_CONTROLLER
Figure 2-2: Showing controllers
HP ProLiant Cluster HA/F500 for MA8000 Enhanced DT Supplement Guide 2-7
HP CONFIDENTIAL
Writer: Bill Akers File Name: c-ch2 Cluster Installation
Codename: Chargers II Part Number: 324547-001 Last Saved On: 4/7/03 10:32 AM