HP ProLiant Cluster HA/F500 for MA8000 Enhanced DT Supplement Guide

Cluster Installation
2. Verify that the access on each unit is set to None by entering the following
command:
SHOW UNITS FULL
The display will be similar to Figure 2-10.
Figure 2-10: Verifying access to each unit
3. Repeat steps 1 and 2 for each unit.
4. Verify that the unit settings are correct by entering the following command:
SHOW UNITS FULL
5. Enter the following commands to distribute the units by setting their
preferred paths:
SET UnitNumber PREFERRED_PATH=THIS_CONTROLLER
SET UnitNumber PREFERRED_PATH=OTHER_CONTROLLER
HP ProLiant Cluster HA/F500 for MA8000 Enhanced DT Supplement Guide 2-15