HP ProLiant Cluster HA/F500 for MA8000 Enhanced DT Supplement Guide
Cluster Installation
12. Restart the controller by entering the following command:
RESTART THIS_CONTROLLER
NOTE: A series of %LFL, %CER, and %EVL prompts are displayed when the controller
restarts. These prompts indicate a Last Failure Log, a CLI Event Report, and an Event
Log. Refer to the StorageWorks HSG80 Array Controller ACS maintenance and service
guide for a complete explanation of these event reports.
13. Use a SHOW THIS command to verify that the WWN has been set.
The display will be similar to Figure 2-15.
HSG80 ZG8nnnnnnn Software V85P, Hardware E03
NODE_ID = nnnn-nnnn-nnnn-nnnn
ALLOCATION CLASS =0
SCSI_VERSION = SCSI 2
Not configured for dual-redundancy
Controller misconfigured--other controller present
Device Port SCSI address 7
Time: NOT SET
Command Console LUN is disabled
Controller:
Figure 2-15: Verifying the WWN
14. Configure the controllers for multibus failover mode by entering the following
command:
SET MULTIBUS_FAILOVER COPY=THIS_CONTROLLER
This command automatically restarts the other controller.
A series of %LFL and %EVL messages are displayed. Refer to the StorageWorks
HSG80 Array Controller ACS maintenance and service guide for more details on
these messages.
HP ProLiant Cluster HA/F500 for MA8000 Enhanced DT Supplement Guide 2-25
HP CONFIDENTIAL
Writer: Bill Akers File Name: c-ch2 Cluster Installation
Codename: Chargers II Part Number: 324547-001 Last Saved On: 4/7/03 10:32 AM