HP ProLiant Cluster HA/F500 for MA8000 Enhanced DT Supplement Guide

Cluster Installation
15. Be sure that the setting from step 14 has been applied by entering the following
command:
SHOW THIS_CONTROLLER FULL
The output shows that the controllers have been configured to support multibus
failovers. The display will be similar to Figure 2-16.
Controller:
HSG80 ZG8nnnnnnn Software V85P, Hardware E03
NODE_ID = nnnn-nnnn-nnnn-nnnn
ALLOCATION_CLASS = 0
SCSI_VERSION = SCSI-2
Configured for MULTIBUS_FAILOVER with ZG8nnnnnnn
In dual-redundant configuration
Device Port SCSI address 7
Time: NOT SET
Command Console LUN is disabled
Figure 2-16: Multibus failover modes
NOTE: The multibus failover settings are automatically applied to controller B.
16. Verify that the settings have been accepted on controller B by entering the
following command:
SHOW OTHER_CONTROLLER FULL
17. Change the controller prompts to help identify which controller is in use by
entering the following commands:
SET THIS_CONTROLLER PROMPT=”InitiatorControllerNameTop
SET THIS_CONTROLLER PROMPT=”InitiatorControllerNameBottom
2-26 HP ProLiant Cluster HA/F500 for MA8000 Enhanced DT Supplement Guide