HP ProLiant Cluster HA/F500 for MA8000 Enhanced DT Supplement Guide

Cluster Installation
28. Verify that these settings are correct by entering the following command:
SHOW THIS_CONTROLLER
The display will be similar to Figure 2-21.
Host PORT_2:
Reported PORT_ID = nnnn-nnnn-nnnn-nnnn
PORT_2_TOPOLOGY = FABRIC (offline)
REMOTE_COPY = SiteA
Figure 2-21: Verifying the settings
Configuring the Storage at the Initiator Site
Add disks, create the storagesets, and create units before configuring the storage for
DRM. Refer to the StorageWorks HSG80 Array Controller ACS configuration guide
for instructions. Keep in mind the restrictions specific to this installation where
noted.
The initiator site must have exactly the same storageset and unit configuration that
the target site has.
IMPORTANT: The SWCC requires that there is at least one LUN defined on the storage
subsystem that is not part of a remote copy set.
To configure the storage, perform the following steps after all the units have been
created:
1. Disable access on all units by entering the following command:
SET UnitName DISABLE_ACCESS_PATH=ALL
HP ProLiant Cluster HA/F500 for MA8000 Enhanced DT Supplement Guide 2-31
HP CONFIDENTIAL
Writer: Bill Akers File Name: c-ch2 Cluster Installation
Codename: Chargers II Part Number: 324547-001 Last Saved On: 4/7/03 10:32 AM