HP ProLiant Cluster HA/F500 for MA8000 Enhanced DT Supplement Guide

Cluster Installation
2. Verify that the target has access to the initiator controller by entering the
following command:
SHOW CONNECTIONS
The display will be similar to Figure 2-23.
Figure 2-23: Verifying connections
3. The target units need to allow access to the controllers at the initiator site. Enable
access to the controllers by entering the following commands:
SET UnitName
ENABLE_ACCESS_PATH=(InitiatorControllerConnectionA,
InitiatorControllerConnectionB,
InitiatorControllerConnectionC,
InitiatorControllerConnectionD)
4. Repeat step 3 for each UnitName.
HP ProLiant Cluster HA/F500 for MA8000 Enhanced DT Supplement Guide 2-35