HP ProLiant Cluster HA/F500 for MA8000 Enhanced DT Supplement Guide

Cluster Installation
6. Verify the switch status of the association set by entering the following
command:
SHOW AssociationSetName
Example: SHOW AS_D1
The display will be similar to Figure 2-29.
Name Association Uses Used by
------------------------------------------------------
AS_D1 association RC_D1
Switches:
NOFAIL_ALL
NOORDER_ALL
LOG_UNIT = D10 (No data logged)
Figure 2-29: Checking the switch status
7. Add any additional remote copy sets to the association set by entering the
following command:
SET AssociationSetName ADD=RemoteCopySetName
8. Verify the switch status of the association set by entering the following
command:
SHOW AssociationSetName
Example: SHOW AS_D1
Configuring the Host at the Initiator Site
Configure the initiator site host to complete the initiator site configuration.
Installing the Host Bus Adapters and Drivers
Install two HBAs in each host. Refer to the HBA documentation for installation
information.
Verifying StorageWorks Fibre Channel Software Installation
Verify that StorageWorks Fibre Channel software is installed. Go to the
Add/Remove Programs screen to verify.
HP ProLiant Cluster HA/F500 for MA8000 Enhanced DT Supplement Guide 2-41