HP ProLiant Cluster HA/F500 for MA8000 Enhanced DT Supplement Guide

Cluster Installation
4. For Windows NT, perform the following:
a. Bring up one node.
NOTE: Verify that the number of LUNs and the number of disks are equal.
b. Run Disk Administrator to create partitions, format, and assign drive letters
on the newly created storage.
c. After the storage is configured, open Partition and select Configuration.
d. Select Save and insert a diskette to create a saved configuration diskette.
NOTE: Create and maintain two copies of the saved configuration at both the initiator and
target sites. This data can be used to restore a known configuration in the event of a site
failover or failback.
e. Shut down the current node, and repeat steps a through e for each
remaining node.
5. Run Secure Path Manager by following this path:
Start\Programs\Secure Path\SPM
Start the application, and specify the preferred server and password. Select the
Save Password checkbox if the same password is used each time for logging in.
6. Verify the drives when the Secure Path Manager screen is displayed.
Right-click the disk that needs verification and select Properties. The Device
Properties window is displayed.
HP ProLiant Cluster HA/F500 for MA8000 Enhanced DT Supplement Guide 2-47