Compaq ProLiant Cluster HA/F500 Enhanced DT Supplement
Introduction
ProLiant Cluster HA/F500 for MA8000 Enhanced DT Supplement Guide 1-7
COMPAQ CONFIDENTIAL
Writer: Woody Jernigan File Name: b-ch1 Introduction
Codename: Chargers Part Number: 165103-004 Last Saved On: 7/30/02 9:23 AM
Basic DT Configuration
The basic DT configuration includes a second target storage subsystem that mirrors
the data on the initiator storage subsystem. The basic DT configuration consists of
the following:
• Two ProLiant servers as cluster nodes
• Two storage subsystems
• Four StorageWorks Fibre Channel SAN Switch 8/8-EL or SAN Switch 16/16-EL
switches
• Two host bus adapters in each server
• Two storage controllers in each storage subsystem
Figure 1-1 shows a basic DT configuration consisting of two separated nodes.
The two nodes plus the initiator storage subsystem form a Microsoft Cluster Server
(MSCS) cluster.
Storage
Subsystem
Switch
Switch
Switch
Switch
Initiator
Target
ProLiant
Server
(Node 1)
FDDI/ATM Network
SITE 1
SITE 2
ProLiant
Server
(Node 2)
Storage
Subsystem
Figure 1-1: Basic DT cluster configuration