Compaq ProLiant Cluster HA/F500 Enhanced DT Supplement

Cluster Installation
ProLiant Cluster HA/F500 for MA8000 Enhanced DT Supplement Guide 2-3
COMPAQ CONFIDENTIAL
Writer: Woody Jernigan File Name: c-ch2 Cluster Installation
Codename: Chargers Part Number: 165103-004 Last Saved On: 7/30/02 9:25 AM
Installing the Hardware
The following sections provide information on installing the hardware components
used in a ProLiant HA/F500 Enhanced DT cluster.
Setting Up the Servers
Refer to the Data Replication Manager HSG80 ACS operations guide for DRM
installation information needed to get the DRM solution ready for setup.
Follow the installation instructions in the ProLiant server documentation to set up
each server as a stand-alone server, and then follow the instructions in the following
sections to configure the cluster.
Setting Up the Storage Subsystem
Refer to the documentation that was shipped with the storage subsystem for detailed
installation instructions.
Host Bus Adapter Requirements and Setup
Install two host bus adapters into the host server to run the DRM solution. Refer to
the host bus adapter guide for detailed information on this hardware.
Locate and record the World Wide Name (WWN) of each host bus adapter. This
number will be needed when renaming the host connections later in the installation
process.
NOTE: The WWN can be found on the bottom of the host bus adapter board. Look for a small
bar code with an Institute of Electrical and Electronics Engineers (IEEE) precursor. WWN
example: 1000-0000-C920-A5BA.