12. Restart the controller by entering the following command:
RESTART THIS_CONTROLLER
NOTE: A series of %LFL, %CER, and %EVL messages are displayed when the controller
restarts. These messages indicate a Last Failure Log, a CLI Event Report, and an Event
Log. Refer to the StorageWorks HSG80 Array Controller ACS maintenance and service
guide for a complete explanation of these event messages.
13. Use a SHOW THIS command to verify that the WWN has been set.
The display will be similar to Figure 2-4.
Controller:
HSG80 ZG8nnnnnnn Software V85P, Hardware E03
NODE_ID =yyyy-yyyy-yyyy-yyyy
ALLOCATION_CLASS =0
SCSI_VERSION =SCSI-2
Not configured for dual-redundancy
Controller misconfigured--other controller present
Device Port SCSI address 7
Time: NOT SET
Command Console LUN is disabled
Figure 2-4: Verifying WWN
14. Configure the controllers for multibus failover mode by entering the following
command:
SET MULTIBUS_FAILOVER COPY=THIS_CONTROLLER
This command automatically restarts the other controller.
A series of %LFL and %EVL messages are displayed. Refer to the StorageWorks
HSG80 Array Controller ACS maintenance and service guide for more details on
these messages.