Compaq ProLiant Cluster HA/F500 Enhanced DT Supplement

Cluster Installation
ProLiant Cluster HA/F500 for MA8000 Enhanced DT Supplement Guide 2-13
COMPAQ CONFIDENTIAL
Writer: Woody Jernigan File Name: c-ch2 Cluster Installation
Codename: Chargers Part Number: 165103-004 Last Saved On: 7/30/02 9:25 AM
24. Set the fabric topology for each port on both controllers by entering the following
commands:
SET THIS_CONTROLLER PORT_1_TOPOLOGY=FABRIC
SET THIS_CONTROLLER PORT_2_TOPOLOGY=FABRIC
SET OTHER_CONTROLLER PORT_1_TOPOLOGY=FABRIC
SET OTHER_CONTROLLER PORT_2_TOPOLOGY=FABRIC
25. Verify that the topology is set correctly by entering the following commands:
SHOW THIS_CONTROLLER
SHOW OTHER_CONTROLLER
The display will be similar to Figure 2-8.
Host Port_1:
Reported PORT_ID =nnnn-nnnn-nnnn-nnnn
PORT_1_TOPOLOGY =FABRIC (offline)
Address =nnnnnnn
NOREMOTE COPY
Host Port_1:
Reported PORT_ID =nnnn-nnnn-nnnn-nnnn
PORT_1_TOPOLOGY =FABRIC (offline)
Address =nnnnnnn
Figure 2-8: Verifying topology
26. Enable the DRM by entering the following command:
SET THIS_CONTROLLER REMOTE_COPY=TargetNodeName
NOTE: Specify a meaningful TargetNodeName such as a name that reflects the target
location. Do not use “local” and “remote”; these are reserved keywords. The name can be
up to eight characters and must be unique to all your controllers. Refer to the
StorageWorks HSG80 Array Controller ACS configuration guide for naming guidelines.
A series of %LFL and %EVL messages are displayed, and the controllers
automatically restart after entering the CLI command.