Codename: Chargers Part Number: 165103-004 Last Saved On: 7/30/02 9:25 AM
27. Verify that these settings are correct by entering the following command:
SHOW THIS_CONTROLLER
The display will be similar to Figure 2-9.
Host PORT_2:
Reported PORT_ID=nnnn-nnnn-nnnn-nnnn
PORT_2_TOPOLOGY=FABRIC (offline)
REMOTE_COPY=SiteB
Figure 2-9: Verifying the settings
Configuring the Storage at the Target Site
Add disks, create the storagesets, and create units before configuring the storage for
DRM. Refer to the StorageWorks HSG80 Array Controller ACS configuration guide
for instructions. Keep in mind the restrictions specific to this installation where
noted.
The target site must have exactly the same storageset and unit configuration that the
initiator site has.
IMPORTANT: The StorageWorks Command Console (SWCC) requires that there be at least
one Logical Unit (LUN) defined on the storage subsystem that is not part of a remote copy set.
To configure the storage, perform the following steps after all the units have been
created:
1. Disable access on all units by entering the following command:
SET UnitNumber DISABLE_ACCESS_PATH=ALL