Compaq ProLiant Cluster HA/F500 Enhanced DT Supplement

Cluster Installation
ProLiant Cluster HA/F500 for MA8000 Enhanced DT Supplement Guide 2-27
COMPAQ CONFIDENTIAL
Writer: Woody Jernigan File Name: c-ch2 Cluster Installation
Codename: Chargers Part Number: 165103-004 Last Saved On: 7/30/02 9:25 AM
18. Verify the SCSI Version and the CCL settings by entering the following
command:
SHOW THIS_CONTROLLER
It is recommended to use SCSI-3 so that the CCL is always enabled. The CCL is
required for scripting failover and failback procedures. For more information on
scripting, refer to the Data Replication Manager HSG80 ACS scripting user
guide.
Set the SCSI Version to SCSI-3 by entering the following command:
SET THIS_CONTROLLER SCSI_VERSION=SCSI-3
19. Verify that the CCL is disabled by entering the following command:
SHOW THIS_CONTROLLER
The display will be similar to Figure 2-17.
HSG80 ZG8nnnnnnn Software V85P, Hardware E03
NODE_ID = nnnn-nnnn-nnnn-nnnn
ALLOCATION CLASS =0
SCSI_VERSION = SCSI 2
Configured for MULTIBUS_FAILOVER with ZG8nnnnnnn
In dual-redundant configuration
Device Port SCSI address 7
Time: NOT SET
Command Console LUN is disabled
Controller:
Figure 2-17: Verifying CCL has been disabled
20. Verify that the settings established for controller A have been applied to
controller B by entering the following command:
SHOW OTHER_CONTROLLER