Compaq ProLiant Cluster HA/F500 Enhanced DT Supplement
Cluster Installation
2-32 ProLiant Cluster HA/F500 for MA8000 Enhanced DT Supplement Guide
COMPAQ CONFIDENTIAL
Writer: Woody Jernigan File Name: c-ch2 Cluster Installation
Codename: Chargers Part Number: 165103-004 Last Saved On: 7/30/02 9:25 AM
2. Verify that the access on each unit is set to None by entering the following
command:
SHOW UNITS FULL
The display will be similar to Figure 2-22.
Figure 2-22: Verifying access to units
3. Repeat steps 1 and 2 for each unit.
4. Verify that the unit settings are correct by entering the following command:
SHOW UNITS FULL
5. Enter the following commands to distribute the units by setting their preferred
path:
SET UnitName PREFERRED_PATH=THIS_CONTROLLER
SET UnitName PREFERRED_PATH=OTHER_CONTROLLER