Compaq ProLiant Cluster HA/F500 Enhanced DT Supplement
Cluster Installation
ProLiant Cluster HA/F500 for MA8000 Enhanced DT Supplement Guide 2-41
COMPAQ CONFIDENTIAL
Writer: Woody Jernigan File Name: c-ch2 Cluster Installation
Codename: Chargers Part Number: 165103-004 Last Saved On: 7/30/02 9:25 AM
6. Verify the switch status of the association set by entering the following
command:
SHOW AssociationSetName
Example: SHOW AS_D1
The display will be similar to Figure 2-29.
Name Association Uses Used by
------------------------------------------------------
AS_D1 association RC_D1
Switches:
NOFAIL_ALL
NOORDER_ALL
LOG_UNIT = D10 (No data logged)
Figure 2-29: Checking the switch status
7. Add any additional remote copy sets to the association set by entering the
following command:
SET AssociationSetName ADD=RemoteCopySetName
8. Verify the switch status of the association set by entering the following
command:
SHOW AssociationSetName
Example: SHOW AS_D1
Configuring the Host at the Initiator Site
Configure the initiator site host to complete the initiator site configuration.
Installing the Host Bus Adapters and Drivers
Install two host bus adapters in each host. Refer to the host bus adapter
documentation for installation information.
Verifying StorageWorks Fibre Channel Software Installation
Verify that StorageWorks Fibre Channel software is installed. Go to the
Add/Remove Programs screen to verify.