Compaq ProLiant Cluster HA/F500 Enhanced DT Supplement

Cluster Installation
2-42 ProLiant Cluster HA/F500 for MA8000 Enhanced DT Supplement Guide
COMPAQ CONFIDENTIAL
Writer: Woody Jernigan File Name: c-ch2 Cluster Installation
Codename: Chargers Part Number: 165103-004 Last Saved On: 7/30/02 9:25 AM
Installing Secure Path
Refer to the SANworks Secure Path for Windows installation guide for installation
information.
Installing StorageWorks Command Console
Installing SWCC is optional. Refer to the StorageWorks Command Console getting
started guide for SWCC installation instructions.
Connecting Fiber Optic Cables Between the Hosts and the Switches
To connect the fiber optic cables between the hosts and switches:
1. Connect the first multimode fiber optic cable from port 0 of the top switch to
the host.
2. Connect the second multimode fiber optic cable from port 0 of the bottom switch
to the host.
The host is now connected to the initiator site by means of multimode fiber optic
cables. The cabling at each site is now complete.
IMPORTANT: Connect the cable to any available port, but maintain the identical scheme
at the initiator site. For example, if port 1 of controller B is connected to port 2 of the
bottom switch at the initiator site, then port 1 of controller B must be connected to port 2 of
the bottom switch at the target site.