— Windows 2000
a. Bring up one node.
NOTE: Restart the server if you receive a message to do so.
b. Expand Disk Drives from the Device Manager utility. Count the number of
drives, divide by 2, and the result should match the number of LUNs you
configured.
c. Run the Disk Management utility to create partitions, format, and assign
drive letters on the newly created storage.
d. Document the disk configuration and keep a copy at each site for later use.
e. Shut down the current node and repeat steps a through e for each
remaining node.
4. Run Secure Path Manager by following this path:
Start\Programs\Secure Path\SPM
Start the application, and specify the preferred server and password. Select the
Save Password box if the same password is used each time for logging in.
5. Verify the drives when the Secure Path Manager screen is displayed.
Right-click the disk that needs verification and select Properties. The Device