Compaq ProLiant CL1850 Software User Guide
System Setup and Configuration for Novell NetWare 2-3
Compaq Confidential – Need to Know Required
Writer: Bryan Hicks Project: Compaq ProLiant CL1850 Software User Guide Comments:
Part Number: 157839-001 File Name: c-ch2 System Setup and Configuration for Novell NetWare.doc Last Saved On: 9/8/99 5:41 PM
6. Arrow down to Compaq 64-Bit Dual Channel Wide Ultra2 SCSI
Controller (Port1). Underneath this heading is a subheading titled SCSI
ID. To change the SCSI ID setting, highlight the SCSI ID option then
press Enter. After making a new selection, press Enter to accept the
change.
IMPORTANT: Make a note of the SCSI ID setting. When server node 2 is configured, it
cannot have the same ID as server node 1. For example, if server node 1 is set for SCSI
ID 6 then server node 2 must be set to ID 7.
7. Press F10 to exit.
8. Select Step 5: Save and Exit, then press Enter.
9. The Product Selection Window appears. Follow the guided installation
process. If you need help refer to the online help by clicking on the Help
button.
10. Once NetWare has been loaded, type Load Install (for NetWare 4.2) or
Nwconfig (for NetWare 5) at the NetWare Console prompt. This allows
you to set up the NetWare disk partitions and to create or modify the
volumes that the system will use.
NOTE: The Compaq 53c876 is the local controller for the internal hard disk drives on the
server nodes. The Compaq 53c896 is the controller device for the shared array controller.
Always install the SYS volume on the local non-shared drives.
Configuring Server Node 2
1. Press Print Screen to access the KVM (Keyboard/Video/Mouse) switch
and choose server node 2 from the list.
For detailed instructions on using the KVM switch, refer to the Compaq
ProLiant CL1850 User Guide.
2. Boot server node 2 with the SmartStart CD in the CD-ROM drive.
3. When the system boots, you will see the Select Language screen. Select
which language you would like to use and follow the installation
process.