Compaq ProLiant CL1850 Software User Guide

2-4 Compaq ProLiant CL1850 Software User Guide
Compaq Confidential Need to Know Required
Writer: Bryan Hicks Project: Compaq ProLiant CL1850 Software User Guide Comments:
Part Number: 157839-001 File Name: c-ch2 System Setup and Configuration for Novell NetWare.doc Last Saved On: 9/8/99 5:41 PM
4. When prompted to select the installation path, select the Assisted
Integration Path. Follow the guided installation process. If you need
help, refer to the online help by clicking on the Help button.
After the operating system has been selected, SmartStart runs the
System Configuration Utility and configures the server nodes hardware.
It is very important that the adapter card in each server node connected
to the shared storage RAID controller have a unique SCSI ID number.
5. To verify or change the SCSI ID number after the system configuration
is done, select Review or Modify Hardware Settings then press Enter.
This allows you to see all of the hardware settings.
6. Select Step 3: View or Edit Details.
7. Arrow down to Compaq 64-Bit Dual Channel Wide Ultra2 SCSI
Controller (Port1). Underneath this heading is a subheading titled SCSI
ID. To change the SCSI ID setting, highlight the SCSI ID option then
press Enter. After making a new selection, press Enter to accept the
change.
IMPORTANT: Make a note of this setting. When server node 2 is configured, it cannot
have the same ID as server node 1. For example, if server node 1 is set for SCSI ID 6 then
server node 2 must be set to ID 7.
8. Press F10 to exit.
9. Select Step 5: Save and Exit, then press Enter.
10. The Product Selection Window appears. Follow the guided installation
process. If you need help, refer to the online help by clicking on the
Help button.
11. Once NetWare has been loaded, type Load Install (for NetWare 4.2) or
Nwconfig (for NetWare 5) at the NetWare Console prompt. This allows
you to set up the NetWare disk partitions and to create or modify the
volumes that the system will use.
12. After the operating system has been successfully installed on both server
nodes, install the appropriate Novell clustering software.