Compaq ProLiant CL380 Software User Guide

4-28 Compaq ProLiant CL380 Software User Guide
Compaq Confidential Need to Know Required
Writer: Linda Arnold Project: Compaq ProLiant CL380 Software User Guide Comments:
Part Number: 157839-004 File Name: e-ch4 CR3500 Configuration Utility.doc Last Saved On: 12/14/00 8:50 AM
If there was no spare drive to use, the logical drive is still in a reduced
state. Add the new physical drive to the logical drive for reconstruction
to start.
a. Select the logical drive in reduced status.
b. Select Logical Drive from the Storage pull-down menu.
c. Select Reconstruct.
d. A list appears showing available drives. Select the drive you just
added.
e. Reconstruction begins.
Setting a Physical Drive as a Spare
NOTE: Spare drives serve as spares to all logical drives. They are not grouped with a
particular logical drive.
How a Spare Drive Works
If a physical drive fails in a RAID 1, RAID 0+1, RAID 4, or RAID 5
logical drive, the spare automatically replaces the failed physical drive
and the controller reconstructs all logical drives that contained the failed
physical drive as a member.
After the controller writes data to a spare, the spare becomes part of the
same device group in which a device failed.
After the controller writes data to a spare, the status of the spare changes
to Good.
To Define a Spare Physical Drive
1. In the main window of the Configuration Utility, click the physical drive
to be used as a spare. The physical drive must be in the Available state.
2. From the Storage menu, choose Physical Drive, then choose Make
Spare.
NOTE: The spare must have a capacity equal to or greater than the failed physical drive
for an automatic reconstruct to start.