Insight Integration for HP Network Node Manager Revision 3.4 User Guide

Table Of Contents
Troubleshooting 98
CPQCHKCONF checks the syntax of CPQCONFIG.DAT.
CPQCHKTCONF checks the syntax of CPQTRAPD.CONF.
CPQCHKSTR checks the syntax of CPQVAL2STR.TRAP and CPQVAL2STR.INFO.
CPQCHKNODE checks the syntax of CPQNODE.DAT.
CPQCHKAUTH displays the authorization details of the HP integration.
Checking the status of background processes
To confirm that the Insight Integration background processes are active, run the OVSTATUS command
from a command line prompt.
The Insight Integration uses two background processes that provide discovery of HP nodes on the NNM
management map and translate HP SNMP events on the NNM Event Browser:
CPQDIS
CPQTRAP
If either of these processes are not displayed as active, configuration or communication problems might
exist. For information about confirming that the Insight Integration is installed correctly, see "Validating the
configuration (on page 97)." For more information, see the HP Network Node Manager User's Guide.
Normally, the process management daemon OVSPMD starts these processes when the operating system
is initialized. If any of these background processes are not running, before initializing the OVW, start
them by entering the OVSTART command. For more information, see the HP Network Node Manager
User's Guide.
Additional resources
The following additional resources are available:
Frequently asked questions
(http://h18000.www1.hp.com/products/servers/management/openview/questionsanswers.html
)
HP Management Integration Support website
(http://h18013.www1.hp.com/products/servers/management/integration.html?jumpid=reg_R100
2_USEN)
HP OpenView user documentation
(ftp://ftp.compaq.com/pub/products/servers/management/HPInsightNNM33.pdf
)